166 research outputs found

    Physical exercise and cardiovascular response:design and implementation of a pediatric CMR cohort study

    Get PDF
    To examine feasibility and reproducibility and to evaluate the cardiovascular response to an isometric handgrip exercise in low-risk pediatric population using Cardiovascular Magnetic Resonance measurements. In a subgroup of 207 children with a mean age of 16 years participating in a population-based prospective cohort study, children performed an isometric handgrip exercise. During rest and exercise, continuous heart rate and blood pressure were measured. Cardiovascular magnetic resonance (CMR) measurements included left ventricular mass, aortic distensibility and pulse wave velocity at rest and left ventricular end-diastolic and end-systolic volumes, ejection fraction, stroke volume and cardiac output during rest and exercise. 207 children had successful CMR measurements in rest and 184 during exercise. We observed good reproducibility for all cardiac measurements. Heart rate increased with a mean ± standard deviation of 42.6% ± 20.0 and blood pressure with 6.4% ± 7.0, 5.4% ± 6.1 and 11.0% ± 8.3 for systolic, diastolic and mean arterial blood pressure respectively (p-values &lt; 0.05). During exercise, left ventricular end-diastolic and end-systolic volumes and cardiac output increased, whereas left ventricular ejection fraction slightly decreased (p-values &lt; 0.05). Stroke volume did not change significantly. A sustained handgrip exercise of 7 min at 30-40% maximal voluntary contraction is a feasible exercise-test during CMR in a healthy pediatric population, which leads to significant changes in heart rate, blood pressure and functional measurements of the left ventricle in response to exercise. This approach offers great novel opportunities to detect subtle differences in cardiovascular health.</p

    Prognostic Value of Subclinical Coronary Artery Disease in Atrial Fibrillation Patients Identified by Coronary Computed Tomography Angiography

    Get PDF
    Identifying coronary artery disease (CAD) in atrial fibrillation (AF) patients improves risk stratification and defines clinical management. However, the value of screening for subclinical CAD with cardiac CT in AF patients is unknown. Between 2011 and 2015, 94 consecutive patients without known or suspected CAD (66 (57–73) years, 68% male), who were referred for AF evaluation, under

    Система управління оборотним капіталом підприємства: елементна структура та ефектівність

    Get PDF
    Метою дослідження є створення комплексної сістеми менеджменту оборотним капіталом та забезпечення її ефективного функціонування. В цьому зв’язку необхідно управляти не лише окремими елементами оборотного капіталу, але і всіма бізнес – процесами підприємства з інтегруванням у стратегічне управління. Це зумовлено тим, що систему управління оборотним капіталом не доцільно розглядати відокремлено від всього підприємства, а її варто досліджувати у комплексі з іншими підсистемами

    Расчет электромагнитного поля в электронных модулях с использованием интеграла Зоммерфельда

    Get PDF
    Излагается подход с использованием интеграла Зоммерфельда. Метод позволяет избежать интегрирования в комплексной области и снизить объем вычислений по сравнению с известными методами

    Coronary calcium scores on dual-source photon-counting computed tomography:an adapted Agatston methodology aimed at radiation dose reduction

    Get PDF
    OBJECTIVES: The aim of this study was to determine mono-energetic (monoE) level-specific photon-counting CT (PCCT) Agatston thresholds, to yield monoE level independent Agatston scores validated with a dynamic cardiac phantom. Also, we examined the potential of dose reduction for PCCT coronary artery calcium (CAC) studies, when reconstructed at low monoE levels. METHODS: Theoretical CAC monoE thresholds were calculated with data from the National Institute of Standards and Technology (NIST) database. Artificial CAC with three densities were moved in an anthropomorphic thorax phantom at 0 and 60-75 bpm, and scanned at full and 50% dose on a first-generation dual-source PCCT. For all densities, Agatston scores and maximum CT numbers were determined. Agatston scores were compared with the reference at full dose and 70 keV monoE level; deviations (95% confidence interval) < 10% were deemed to be clinically not-relevant. RESULTS: Averaged over all monoE levels, measured CT numbers deviated from theoretical CT numbers by 6%, 13%, and - 4% for low-, medium-, and high-density CAC, respectively. At 50% reduced dose and 60-75 bpm, Agatston score deviations were non-relevant for 60 to 100 keV and 60 to 120 keV for medium- and high-density CAC, respectively. CONCLUSION: MonoE level-specific Agatston score thresholds resulted in similar scores as in standard reconstructions at 70 keV. PCCT allows for a potential dose reduction of 50% for CAC scoring using low monoE reconstructions for medium- and high-density CAC. KEY POINTS: • Mono-energy level-specific Agatston thresholds allow for reproducible coronary artery calcium quantification on mono-energetic images. • Increased calcium contrast-to-noise ratio at reduced mono-energy levels allows for coronary artery calcium quantification at 50% reduced radiation dose for medium- and high-density calcifications

    Исследование характеристик щелевого теплообменника с развитой поверхностью теплообмена

    Get PDF
    Предложена конструкция водяного многоканального щелевого теплообменника, позволяющего отводить мощность до 750 Вт при температуре имитатора теплового потока 60°С, а также пути повышения технологичности изготовления теплообменника

    Preoperative Chest Computed Tomography Screening for Coronavirus Disease 2019 in Asymptomatic Patients Undergoing Cardiac Surgery

    Get PDF
    Due to the outbreak of Severe Acute Respiratory Syndrome coronavirus (SARS-Cov-2), an efficient COVID-19 screening strategy is required for patients undergoing cardiac surgery. The objective of this prospective observational study was to evaluate the role of preoperative computed tomography (CT) screening for COVID-19 in a population of COVID-19 asymptomatic patients scheduled for cardiac surgery. Between the 29th of March and the 26th of May 2020, patients asymptomatic for COVID-19 underwent a CT-scan the day before surgery, with reverse-transcriptase polymerase-chain reaction (RT-PCR) reserved for abnormal scan results. The primary endpoint was the prevalence of abnormal scans, which was evaluated using the CO-RADS score, a COVID-19 specific grading system. In a secondary analysis, the rate of abnormal scans was compared between the screening cohort and matched historical controls who underwent routine preoperative CT-screening prior to the SARS-Cov-2 outbreak. Of the 109 patients that underwent CT-screening, an abnormal scan result was observed in 7.3% (95% confidence interval: 3.2–14.0%). One patient, with a normal screening CT, was tested positive for COVID-19, with the first positive RT-PCR on the ninth day after surgery. A rate of preoperative CT-scan abnormalities of 8% (n = 8) was found in the unexposed historical controls (P &gt; 0.999). In asymptomatic patients undergoing cardiac surgery, preoperative screening for COVID-19 using computed tomography will identify pulmonary abnormalities in a small percentage of patients that do not seem to have COVID-19. Depending on the prevalence of COVID-19, this results in an unfavorable positive predictive value of CT screening. Care should be taken when considering CT as a screening tool prior to cardiac surgery.</p

    Dose Reduction in Coronary Artery Calcium Scoring Using Mono-Energetic Images from Reduced Tube Voltage Dual-Source Photon-Counting CT Data:A Dynamic Phantom Study

    Get PDF
    In order to assess coronary artery calcium (CAC) quantification reproducibility for photon-counting computed tomography (PCCT) at reduced tube potential, an anthropomorphic thorax phantom with low-, medium-, and high-density CAC inserts was scanned with PCCT (NAEOTOM Alpha, Siemens Healthineers) at two heart rates: 0 and 60–75 beats per minute (bpm). Five imaging protocols were used: 120 kVp standard dose (IQ level 16, reference), 90 kVp at standard (IQ level 16), 75% and 45% dose and tin-filtered 100 kVp at standard dose (IQ level 16). Each scan was repeated five times. Images were reconstructed using monoE reconstruction at 70 keV. For each heart rate, CAC values, quantified as Agatston scores, were compared with the reference, whereby deviations >10% were deemed clinically relevant. Reference protocol radiation dose (as volumetric CT dose index) was 4.06 mGy. Radiation dose was reduced by 27%, 44%, 67%, and 46% for the 90 kVp standard dose, 90 kVp 75% dose, 90 kVp 45% dose, and Sn100 standard dose protocol, respectively. For the low-density CAC, all reduced tube current protocols resulted in clinically relevant differences with the reference. For the medium- and high-density CAC, the implemented 90 kVp protocols and heart rates revealed no clinically relevant differences in Agatston score based on 95% confidence intervals. In conclusion, PCCT allows for reproducible Agatston scores at a reduced tube voltage of 90 kVp with radiation dose reductions up to 67% for medium- and high-density CAC

    Sex-specific aortic valve calcifications in patients undergoing transcatheter aortic valve implantation

    Get PDF
    To study sex-specific differences in the amount and distribution of aortic valve calcification (AVC) and to correlate the AVC load with paravalvular leakage (PVL) post-transcatheter aortic valve intervention (TAVI). This registry included 1801 patients undergoing TAVI with a Sapien3 or Evolut valve in two tertiary care institutions. Exclusion criteria encompassed prior aortic valve replacement, suboptimal multidetector computed tomography (MDCT) quality, and suboptimal transthoracic echocardiography images. Calcium content and distribution were derived from MDCT. In this study, the median age was 81.7 (25th–75th percentile 77.5–85.3) and 54% male. Men, compared to women, were significantly younger [81.2 (25th–75th percentile 76.5–84.5) vs. 82.4 (78.2–85.9), P ≤ 0.01] and had a larger annulus area [512 mm 2 (25th–75th percentile 463–570) vs. 405 mm 2 (365–454), P < 0.01] and higher Agatston score [2567 (25th–75th percentile 1657–3913) vs. 1615 (25th–75th percentile 905–2484), P < 0.01]. In total, 1104 patients (61%) had none-trace PVL, 648 (36%) mild PVL, and 49 (3%) moderate PVL post-TAVI. There was no difference in the occurrence of moderate PVL between men and women (3% vs. 3%, P = 0.63). Cut-off values for the Agatston score as predictor for moderate PVL based on the receiver-operating characteristic curve were 4070 (sensitivity 0.73, specificity 0.79) for men and 2341 (sensitivity 0.74, specificity 0.73) for women. AVC is a strong predictor for moderate PVL post-TAVI. Although the AVC load in men is higher compared to women, there is no difference in the incidence of moderate PVL. Sex-specific Agatston score cut-offs to predict moderate PVL were almost double as high in men vs. women
    corecore